Skip to main content

Home & Building Calculators

Heating and Cooling Calculator

The room mode sizes heating or cooling for one room from its floor area, ceiling height, sun and occupants. The radiator mode works out what a radiator delivers at your water and room temperatures. The air-conditioner mode turns a sum of room loads into tons of cooling. These are rules of thumb, not a full load calculation.

United States edition

Calculator

Formula

Room: floor area × BTU/h per sq ft, × height scale, × 1.1 if sunny, + 600 BTU/h per person beyond two, rounded up to 100 BTU/h. Radiator: output = rated × (actual difference ÷ rated difference)^1.3. Air conditioner: required = room sum × (1 + allowance); tons = required ÷ 12,000, rounded up to the next half ton. Sources: rules of thumb from US Department of Energy consumer sizing guidance; the EN 442 radiator rating at a 50 K difference and its power law; the ton of refrigeration (12,000 BTU/h).

About This Calculator

What It Does

This calculator answers three sizing questions. Room mode multiplies the floor area by a rate of heat or cooling per square foot (25 BTU/h, the commonly published rule of thumb), scales the result for ceilings above 8 ft, adds 10 % for a room with strong direct sun, and adds 600 BTU/h for each person beyond two. Radiator mode applies the power law, output = rated × (actual difference ÷ rated difference)^1.3, to the rated output. Air-conditioner mode adds a safety allowance to a sum of room loads, divides by 12,000 BTU/h per ton and rounds up to the next half ton.

Worked Example

Example: a 15 × 12 ft living room with 8 ft ceilings, strong sun and two people has 180 sq ft × 25 BTU/h = 4,500 BTU/h, plus 10 % for sun = 4,950, rounded to 5,000 BTU/h. A radiator rated 3,412 BTU/h at a 90 °F difference, running at 140 °F water in a 68 °F room (a 72 °F difference), gives 3,412 × (72 ÷ 90)^1.3 ≈ 2,553 BTU/h. Three rooms totalling 18,000 BTU/h with a 10 % allowance need 19,800 BTU/h, which is 1.65 tons, sized to 2 tons.

Real-World Usage

Use room mode before you buy a portable or wall air conditioner for one room, or before you ask how many radiators a room needs. Use radiator mode to check whether a radiator rated at the maker's figure still covers a room at the water temperature the boiler really runs. Use air-conditioner mode with the sum of every room you want cooled, to get the tonnage to ask an installer for.

Local Context

The sizing rules are the same wherever you live, but the units differ. US and Canadian sellers quote BTU per hour and tons. Most of Europe and the UK quote watts and kilowatts, and the metric form shows the watt and kilowatt figure beside each result. European radiators are usually rated at the EN 442 standard, a 50 K difference, and a boiler's water in a cold winter runs hotter than the rating assumes. Ask the installer for the design temperature of your region before you size a system by hand.

Last reviewed: November 2026.

Frequently Asked Questions

How many BTU per hour does a 15 × 12 ft room need?

With 8 ft ceilings, two people and no strong sun, 180 sq ft at the 25 BTU/h per square foot rule of thumb is 4,500 BTU/h. A sunny room adds 10 %, which gives 4,950 and rounds up to 5,000 BTU/h.

Why does a radiator give less heat than its rating?

A radiator is rated at a 50 K (90 °F) difference between its water and the room. At a smaller difference the output falls faster than the difference, by the power 1.3 that EN 442 radiators typically follow. At 72 °F the 3,412 BTU/h rating gives about 2,553 BTU/h.

How many tons of air conditioning do I need?

One ton is 12,000 BTU/h. Add a safety allowance to the sum of the room loads, divide by 12,000 and round up to the next half ton. 18,000 BTU/h with a 10 % allowance is 19,800 BTU/h, or 1.65 tons, sized to 2 tons.

Is this a full load calculation?

No. A full room-by-room load calculation, such as ACCA Manual J or an equivalent, uses insulation, windows, air leakage and local design temperatures. This page uses published rules of thumb and the radiator power law. Use it for an estimate, and ask an installer for a full calculation before you buy equipment.

Related Tools